AVENTICS-R412088225

AVENTICS™ Series AES R412088225

선정 제품 설명

AES-D-BC-ECAT-GEN2

Version
Bus coupler
Type
Generation 2
Fieldbus protocol
EtherCAT
E/A capable
connection with I/O
Number of I/O connections
512 inputs / 512 outputs
Power plug IN type
Plug
Power plug IN size
M12x1
Power plug IN number of pole
4-pin
Power plug IN coding
A-coded
Fieldbus design
D-design
Min. ambient temperature
-10 °C
Max. ambient temperature
60 °C
Number of solenoid coils max.
128
Max. number of valve positions
64
Operational voltage electronics
24 V DC
Electronics voltage tolerance
-25% / +25%
Current consumption electronics
0.1 A
Operating voltage, actuators
24 V DC
Total output for valves
4 A
Protection class
IP65
Cycle time at 256 bits
< 1 ms
Logic/actuator voltage
Galvanically isolated
Diagnosis
System error, Undervoltage
I/O module extension max.
10
Generic emission standard in accordance with norm
EN 61000-6-4

특징

  • 최소 치수
  • 보호 단계 IP65
  • 공압 응용 분야에 적합한 특별 I/O-모듈
  • 최적화된 배선
  • OPC UA 통합을 통해 PLC를 변경하거나 만지지 않고도 데이터 및 분석에 쉽게 액세스할 수 있습니다
  • 통합 디지털 트윈은 생산성과 효율성을 향상시킵니다